Metallic implants and CT artefacts in the CTV area: Where are we in 2020? - Institut Curie Access content directly
Journal Articles Cancer/Radiothérapie Year : 2020

Metallic implants and CT artefacts in the CTV area: Where are we in 2020?

A. Rousselle
  • Function : Author
A. Amelot
  • Function : Author
J. Jacob
  • Function : Author
G. Mercy
  • Function : Author
L. Feuvret
  • Function : Author

Abstract

Radiation therapy (RT) is one of the main modalities of cancer treatment worldwide with computed tomography (CT), as the most commonly used imaging method for treatment planning system (TPS). Image reconstruction errors may greatly affect all the radiation therapy planning process, such as target delineation, dose calculation and delivery, particularly with particle therapy. Metallic implants, such as hip and spinal implants, and dental filling significantly deteriorate image quality. These hardware structures are often very complex in geometry leading to geometric complex artefacts in the clinical target volume (CTV) area, rendering the delineation of CTV challenging. In our review, we focus on the methods to overcome artefact consequences on CTV delineation: 1– medical approaches anticipating issues associated with imaging artefacts during preoperative multidisciplinary discussions while following standard recommendations; 2– common metal artefact reduction (MAR) methods such as manually override artefact regions, ballistics avoiding beam paths through implanted materials, megavoltage-CT (MVCT); 3– prospects with radiolucent implants, MAR algorithms and various methods of dual energy computed tomography (DECT). Despite substantial and broad evidence for their benefits, there is still no universal solution for cases involving implanted metallic devices. There is still a high need for research efforts to adapt technologies to our issue: “how do I accurately delineate the ideal CTV in a metal artefact area?”
Fichier principal
Vignette du fichier
S1278321820301980.pdf (286.01 Ko) Télécharger le fichier
Origin : Files produced by the author(s)

Dates and versions

hal-03022643 , version 1 (21-09-2022)

Licence

Attribution - NonCommercial

Identifiers

Cite

A. Rousselle, A. Amelot, J. Thariat, J. Jacob, G. Mercy, et al.. Metallic implants and CT artefacts in the CTV area: Where are we in 2020?. Cancer/Radiothérapie, 2020, 24 (6-7), pp.658-666. ⟨10.1016/j.canrad.2020.06.022⟩. ⟨hal-03022643⟩
38 View
96 Download

Altmetric

Share

Gmail Facebook Twitter LinkedIn More